RE: "Cantilevered Column" Structures
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: "'seaint(--nospam--at)seaint.org'" <seaint(--nospam--at)seaint.org>
- Subject: RE: "Cantilevered Column" Structures
- From: Matt Dotta <Matt.Dotta(--nospam--at)StarBuildings.net>
- Date: Thu, 19 Jul 2001 13:35:26 -0700
Most metal building companies would probably design the r.f. with 4.5 regardless of the foundation restraints. I don't believe that the cantilevered column situation applies here as the metal building bracing is separate from the foundation. The foundation most likely is much more than 10x the stiffeness of the metal building. Matthew Dotta Star Building Systems (405) 636-2441 -----Original Message----- From: Kevin Harris [mailto:Kevinh(--nospam--at)jhiengineering.com] Sent: Thursday, July 19, 2001 3:24 PM To: Seaint(--nospam--at)seaint.org Subject: "Cantilevered Column" Structures Greetings I have a question that has been bugging me for awhile that I hope someone can give me some guidance on. Here are the facts: 1) A lightweight pre-engineered building (say 20 psf) bearing on a pile supported mat that supports tanks and equipment (say 500 psf+). 2) UBC seismic zone 3. 3) Point of fixity of piles is 20 ft below grade, per geotech. Would this structure have to be considered a "cantilevered column building system" (R=2.2)? I was wondering if I would be released from this low R value because the structure is essentially just an equipment foundation. Also, if I have to use R=2.2 for the foundation, would the light metal building shell have to be designed with R=2.2 as well (unless it can be shown to have 10 times the metal building stiffness)? Thank you for your thoughts. Kevin Harris, P.E. * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org
- Prev by Subject: Re: "Cantilevered Column" Structures
- Next by Subject: RE: "Cantilevered Column" Structures
- Previous by thread: Re: "Cantilevered Column" Structures
- Next by thread: RE: "Cantilevered Column" Structures
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]